Olympus cellSens imaging software packages enable archiving, the analysis of multistained specimens and semi-automated experiments with live cells. Basic and integrated solutions are available for time-lapse imaging, multiple image alignment, high content screening and more.
The IX81 inverted research microscope with advanced UIS2 objectives provides the highest standards of observation and functional operation for research applications, and not only in live cell imaging. A flexible modular automation system enables adaptation for different research purposes through the addition of motorised modules such as condensers, filter wheels, shutters and stages, all of which are controlled by a hand switch or Olympus imaging software. The range of experimental protocols possible is expanded by the flexible multiport concept, which facilitates highly customised configurations.
Add to watch listLive cell imaging solutions
Modular automation
The fully automatable IX81 has an integrated motorised high-precision Z-drive, motorised nosepiece, motorised lightpath changer and programmable frame keys. Additional motorised modules include condensers, filter wheels, shutters and stages, all of which are controlled by a hand switch or Olympus software.
Dedicated to fluorescence
Olympus multiple fluorescence illumination systems and high-definition ion coated filters provide the highest signal-to-noise performance. The wavelength accuracy, edge steepness and low autofluorescence of the HQ fluorescence filters reveal more detail. Innovative fluorescence detection methods and the disc scanning confocal unit expand the view of surface phenomena and produce live 3D images.
Multiport concept
No other microscope system offers greater flexibility. The IX71 and IX81 microscope frames are designed as an optical bench and are equipped with several illumination and detection ports to enable versatile port configurations for a variety of experimental techniques.
Slim and rigid
The IX2 inverted research frames are unsurpassed in compactness without any compromise to their rock-like stability.
UIS2 - Making the invisible visible
The UIS2 objective series reveals previously unseen details and protects cells from harmful radiation. Superb signal-to-noise performance in an enhanced spectral range delivers maximum signal with minimum excitation power. All contrast techniques for living cells can be selected, including pre-centred phase contrast and relief contrast for accurate and clear, 3D-like images. The flexible UIS2 DIC enables contrast adjustment for thin and thick specimens at every magnification.
Fully motorised advanced microscopy
The IX81 provides the highest standards of observation and functional operation as well as the performance required for accurate research applications. The motorised system can be adapted for different research purposes and provides excellent, customisable solutions for imaging, analysis and manipulation.
| Microscope body | Optical system | UIS2 |
|---|---|---|
| Focus | Vertical movement: 9 mm stroke with upper limit stopper, coaxial coarse and fine focusing knobs are directly connected to encoder (minimum fine focus graduation: 1 µm, full rotation of fine focusing knobs: 100 µm) | |
| Primary image port | Lower branch: Left side port: S1F 100%. Upper branch: Optional right side port or upper back port selectable when built-in magnification changer 1X/1.6X is replaced (2-step light path selection) | |
| Frontal operation | Light path selector button, transmitted light intensity control buttons and light ON/OFF switch button, fine/coarse selector button, TTL pulse control (auxiliary) buttons | |
| Revolving nosepiece | Sextuple motorised with objective lens retraction in PC mode, simple waterproof mechanism incorporated | |
| Transmitted light illuminator | 100 W halogen lamp | |
| Illumination pillar tilt mechanism with 30° inclination angle and vibration-reducing mechanism | ||
| Condenser holder with 50 mm stroke included, swing-in/out mechanism | ||
| Field iris diaphragm adjustable | ||
| 4 filter holders (ø45 mm, t = 6 mm or less) | ||
| Observation Tube | Widefield (FN22) | Widefield tilting binocular, inclined 35–85°, eyepoint height range: 406 mm–471mm, interpupillary distance adjustable between 50–76 mm, dioptre adjustment function, erect image |
| Widefield binocular, with centring telescope, inclined 90°, interpupillary distance adjustable 50–76 mm, dioptre adjustment function | ||
| Widefield binocular, inclined 90°, interpupillary distance adjustable 50–76 mm, dioptre adjustment function | ||
| Widefield trinocular, inclined 30°, 3-step optical path selectable (100:0, 20:80, 0:100), interpupillary distance adjustable 50–76 mm, dioptre adjustment function | ||
| Stage | Ceramic-coated coaxial stage with right-hand drive control, 50 mm (X) x 50 mm (Y) stroke, stage insert plate exchangeable (ø 110 mm) | |
| Ceramic-coated coaxial stage with short left handle, 50 mm (X) x 43 mm (Y) stroke, stage insert plate exchangeable (ø 110 mm) | ||
| Ceramic-coated plain stage, 232 mm (X) x 240 mm (Y) stage size, stage insert plate exchangeable (ø 110 mm) | ||
| Specimen guide to be used with plain stage, 130 mm (X) x 85 mm (Y) stroke | ||
| Ceramic-coated narrow plain stage, 160 mm (X) x 240 mm (Y) stage size, stage insert plate exchangeable (ø 110 mm) | ||
| Specimen guide to be used with narrow plain stage, 120 mm (X) x 78 mm (Y) stroke | ||
| Ceramic-coated upper circular stage, 360° rotatable, 20 mm (X/Y) travel | ||
| Condenser | Universal, 8 positions for optical devices (5 positions for ø 30 mm, 3 positions for ø 30 mm), aperture iris diaphragm adjustable, with dry front lens NA 0.9/WD 1.5, with oil immersion front lens NA 1.4/WD 0.6 | |
| Long universal working distance, 5 positions for optical devices (3 positions for ø 30 mm and 2 positions for ø 38 mm), aperture iris diaphragm adjustable, NA 0.55/WD 27 mm | ||
| Long working distance relief contrast, 4 positions for optical devices (for ø 50 mm, relief contrast optical devices rotatable), aperture iris diaphragm adjustable, NA 0.5/WD 45 mm | ||
| Ultra long working distance phase contrast, 4 positions for optical devices (for ø 29 mm), aperture iris diaphragm adjustable, NA 0.3/WD 73 mm | ||
| DIC, single position for optical device (include 2 optical device holders), 40° injection pipette or electrode insertion angle, aperture iris diaphragm adjustable, with water immersion front lens NA 0.9/WD 3.7 mm, with dry front lens NA 0.9/WD 1.5, with oil immersion front lens NA 1.4/WD 0.6 | ||
| Motorised universal long working distance, 6 positions for optical devices (3 positions for ø 30 mm and 2 position for ø 38 mm), aperture iris diaphragm adjustable, NA 0.55/WD 27 mm | ||
| Reflected light fluorescence unit | L-shaped fluorescence illuminator, exchangeable F.S. and A.S. modules, 2 filter holder sliders (2 positions, ø 32 mm, t = 6 mm or less) | |
| Straight fluorescence illuminator with field iris diaphragm, filter holder slider (2 positions, ø 32 mm, t = 6 mm or less) | ||
| Fluorescence cube turret, 6 positions in a rotating turret, built-in shutter | ||
| Fast motorised turret, 6 positions, built-in shutter, switching speed ≤300 ms, requires xcellence or cellSens software | ||
| 100 W Hg lamp housing and transformer, or 75 W Xe lamp housing and transformer | ||
| Motorised turret with 6 positions, built-in shutter |
-
Product-BrochureIX71 & IX81 family brochure
More details- 4.11 MB
- Download
-
System ChartIX71 IX81 system chart
More details- 2.29 MB
- Download
-
ManualIX81 manual
More details- 2.08 MB
- Download
-
Application ReportIX81 application report
More details- 477 KB
- Download
-
Product-BrochureIX71 IX81 product brochure
More details- 2.11 MB
- Download
-
Product-BrochureIX71 IX81 product brochure
More details- 5.2 MB
- Download
-
Product-BrochureIX71 IX81 product brochure
More details- 2.16 MB
- Download
-
ManualIX81 manual
More details- 1.8 MB
- Download
-
ManualIX81 manual
More details- 2.01 MB
- Download
-
ManualIX81 manual
More details- 1.76 MB
- Download
-
ManualIX81 manual
More details- 2.07 MB
- Download
-
ManualIX81 manual
More details- 2.05 MB
- Download
-
ManualIX81 manual
More details- 1.86 MB
- Download
-
ManualIX81 manual
More details- 1.81 MB
- Download
-
ManualIX81 manual
More details- 2 MB
- Download
-
ManualIX81 manual
More details- 1.81 MB
- Download
-
ManualIX81 manual
More details- 1.77 MB
- Download
-
ManualIX81 manual
More details- 1.8 MB
- Download
-
ManualIX81 manual
More details- 1.76 MB
- Download
-
ManualIX81 manual
More details- 1.8 MB
- Download
Live Cell Imaging
Functional Modules
High Content Screening
Bioluminescence Imaging
All-in-one cLSM
Confocal LSM
Multiphoton LSM
Upright Microscopes
Inverted Microscopes
Stereo Microscopes
All-in-one Microscopes
Virtual Slide Microscopes
Colour Cameras
Monochrome Cameras
Colour & Monochrome Cameras
cellSens
labSens
xcellence
Objectives
Light Sources
Fluorescence Filters for BX3
Fluorescence Filters for BX2/IX2